Question : 6 of 54
Marks: +1, -0
A galvanometer is used to detect or/and measure small currents in an electrical circuit. It essentially works on the fact that a current-carrying coil experiences a deflecting torque when placed in a magnetic field. This deflection in the coil can be measured and it is related to the current flowing in the coil, the number of turns in the coil, area of the coil and the magnetic field. A hair spring attached to the coil provides a counter torque and helps in measuring the deflection. A galvanometer can be converted to an ammeter or a voltmeter of desired range by using suitable resistances.
(I) The torque on the coil remains constant irrespective of the coil's orientation during rotation due to
(A) use of soft iron core which increases the magnetic field.
(B) radial magnetic field
(C) hair spring which provides the counter torque
(D) eddy current in the iron core which causes damping.
(II) The best way to increase current sensitivity of a galvanometer is by
(A) increasing number of turns of the coil
(B) increasing area of coil and magnetic field strength
(C) decreasing area of coil and magnetic field strength
(D) increasing torsional constant of the hair spring
(III) A moving coil galvanometer has a coil with area of cross-section 4.0×10−3 m24.0 \times 10^{-3} \text{ m}^2 and number of turns 5050. The coil is rotating in a magnetic field of 0.25 T0.25 \text{ T}. The torque acting on the coil when a current of 5 A5 \text{ A} passes through it is
(A) 1.0 N m1.0 \text{ N m}
(B) 2.0 N m2.0 \text{ N m}
(C) 0.50 N m0.50 \text{ N m}
(D) 0.25 N m0.25 \text{ N m}
OR
A galvanometer coil has a resistance of 15 Ω15 \ \Omega and the meter shows full scale deflection for a current of 3 mA3 \text{ mA}. The value of resistance required to convert it into a voltmeter of range (0−12 V)(0 - 12 \text{ V}) is
(A) 4015 Ω4015 \ \Omega
(B) 3985 Ω3985 \ \Omega
(C) 415 Ω415 \ \Omega
(D) 385 Ω385 \ \Omega
(IV) A galvanometer with coil of resistance 20 Ω20 \ \Omega shows full scale deflection for a current of 5 mA5 \text{ mA}. To convert it into an ammeter of range (0−10 A)(0 - 10 \text{ A}), a resistance of
(A) 0.05 Ω0.05 \ \Omega should be connected in series with it.
(B) 0.05 Ω0.05 \ \Omega should be connected in parallel with it.
(C) 0.01 Ω0.01 \ \Omega should be connected in parallel with it.
(D) 0.01 Ω0.01 \ \Omega should be connected in series with it.
[CBSE 2026 55/1/3]
Solution:  
Concept:
Torque on the coil: τ=NIABsin⁡θ\tau = NIAB\sin\theta. In a radial field the plane of the coil is always parallel to BB, so τ=NIAB\tau = NIAB. At equilibrium NIAB=kϕNIAB = k\phi, so ϕ=NABkI\phi = \dfrac{NAB}{k}I and the current sensitivity is ϕI=NABk\dfrac{\phi}{I} = \dfrac{NAB}{k}.
(I) The concave pole pieces and the soft-iron core make the field radial, so the angle between the plane of the coil and BB stays 0∘0^\circ in every position and τ=NIAB\tau = NIAB does not depend on orientation. The soft-iron core only strengthens the field, the spring gives the restoring torque and eddy currents give damping.
Answer: (B) radial magnetic field
(II) Current sensitivity =NABk= \dfrac{NAB}{k}. Increasing NN is the practical way to raise it: a larger coil area makes the coil heavy and bulky, and the field is limited by the magnet available. Decreasing AA and BB or increasing kk lowers the sensitivity.
Answer: (A) increasing number of turns of the coil
(III) τ=NIAB=50×5×4.0×10−3×0.25=0.25 N m\tau = NIAB = 50 \times 5 \times 4.0 \times 10^{-3} \times 0.25 = 0.25 \text{ N m}
Answer: (D) 0.25 N m0.25 \text{ N m}
OR (III) A large resistance RR is joined in series: Ig(G+R)=VI_g(G + R) = V
R=VIg−G=123×10−3−15=4000−15=3985 ΩR = \dfrac{V}{I_g} - G = \dfrac{12}{3 \times 10^{-3}} - 15 = 4000 - 15 = 3985 \ \Omega
Answer: (B) 3985 Ω3985 \ \Omega
(IV) A small shunt SS is joined in parallel: IgG=(I−Ig)SI_g G = (I - I_g)S
S=IgGI−Ig=5×10−3×2010−0.005=0.19.995≈0.01 ΩS = \dfrac{I_g G}{I - I_g} = \dfrac{5 \times 10^{-3} \times 20}{10 - 0.005} = \dfrac{0.1}{9.995} \approx 0.01 \ \Omega
Answer: (C) 0.01 Ω0.01 \ \Omega should be connected in parallel with it.