(a) (i) A resistor and a capacitor are connected in series to an ac source . Derive an expression for the impedance of the circuit.(ii) When does an inductor act as a conductor in a circuit ? Give reason for it.(iii) An electric lamp is designed to operate at 110 V dc and 11 A current. If the lamp is operated on 220 V, 50 Hz ac source with a coil in series, then find the inductance of the coil.OR(b) (i) Draw a labelled diagram of a step-up transformer and describe its working principle. Explain any three causes for energy losses in a real transformer.(ii) A step-up transformer converts a low voltage into high voltage. Does it violate the principle of conservation of energy ? Explain.(iii) A step-up transformer has 200 and 3000 turns in its primary and secondary coils respectively. The input voltage given to the primary coil is 90 V. Calculate :(1) The output voltage across the secondary coil(2) The current in the primary coil if the current in the secondary coil is 2.0 A.
[CBSE 2024 55/1/2]
Solution:
(a)(i) Let the current be (the same through R and C in series).Voltage across R: , in phase with ; amplitude .Voltage across C: , lagging by ; amplitude , where .Phasor diagram:
Since , the phasor is the vector sum of the two perpendicular phasors:The current leads the voltage by , where .(a)(ii) An inductor acts as a conductor for a steady current (dc). Its reactance is ; for dc , so . Also, with no change in current () no back emf is induced, so only the small resistance of its wire opposes the current.(a)(iii) Resistance of the lamp: On the ac source the current must still be A (rms):Result: mHOR (b)(i) Labelled diagram of a step-up transformer:
Principle: mutual induction. Working: when an alternating voltage is applied to the primary coil, the alternating current produces an alternating magnetic flux in the soft-iron core. This flux links the secondary coil and induces an alternating emf in it. With the same flux per turn, and , so . In a step-up transformer , so .Causes of energy loss (any three):1. Flux leakage: not all the flux of the primary links the secondary (reduced by winding the coils over each other).2. Resistance of the windings: current in the copper wires produces Joule heating ( loss); reduced by using thick wires.3. Eddy currents: the alternating flux induces eddy currents in the iron core, which heat it; reduced by using a laminated core.4. Hysteresis: the core is magnetised and demagnetised every cycle and energy is lost as heat; reduced by using soft iron (low hysteresis loss).(b)(ii) No. A step-up transformer raises the voltage but lowers the current in the same ratio. For an ideal transformer the output power equals the input power, , so . No energy is created; in a real transformer the output power is even slightly less than the input.(b)(iii) Given: , , V, A(1) V(2) AResult: V, A


© examsnet.com
Go to Question: